- Light
- 120,000 lm
- Mast
- 30 ft
- Gen
- 8 kW
Six LED heads, solar first, with an auto-start diesel generator for long nights. Built for highway crews, mines and 24-hour work zones.
How solar power works on the Beacon H6 Hybrid
Monocrystalline panels charge a LiFePO4 battery bank through a charge controller. The cameras, lights or outlets run from the battery around the clock. During the day the panels cover the load and refill the battery; at night and through cloudy spells the battery carries everything. The figure that matters is autonomy: how many days the battery can run the load with no useful sun.
Light towers are the hardest load for solar, because all the demand comes at night and it is large. The runtime figures in the spec table assume 12 hours per night, and dimming after midnight is what stretches a battery through cloudy spells.
In its standard build, the Beacon H6 Hybrid carries a 20.5 kWh LiFePO₄ battery bank and a 1,600 W monocrystalline array. The standard build also has a 8 kW diesel, auto start on low battery generator.
When to choose this configuration
Choose solar when the site has a reasonable view of the southern sky, the load is modest, and you want no fuel, no noise and almost no running cost. It is the default for most camera and light trailers in the range.
The standard Beacon H6 Hybrid ships with a diesel generator. Choosing solar power changes the power system; the mast, sensors and chassis stay the same. The figures below describe the standard build, so ask for autonomy and runtime figures for this configuration.
Why people choose the Beacon H6 Hybrid
The H6 Hybrid is the high-output tower: six 200 W LED heads, 120,000 lumens on a 30 ft hydraulic mast. It runs solar first and starts its 8 kW diesel generator only when the battery is low; the catalogue quotes up to 80% less fuel than diesel-only towers and about 30 days on a 40 gal tank. Auxiliary outlets power tools.
- Crews work through the night, every night
- The site is far from refuelling and you want fewer fuel runs
- You need 120 V and 240 V outlets at the tower
Charging and power supply
There is nothing to refuel. Keep the panels clear: brush off snow, rinse heavy dust and check that nothing new shades the array, such as a stockpile, a parked crane or a site office. Check battery state of charge in the app each morning. If the charge trends downwards over several days, reduce the load (dim lights, lower frame rates) or arrange a generator top-up before the battery reaches its cut-off.
This configuration in numbers
Rule of thumb for this build: the 1,600 W monocrystalline array would need about 13 hours of full rated output to refill the 20.5 kWh LiFePO₄ bank from empty. On a clear summer day that is achievable over a day or two; on a short December day with low sun, real output is a small fraction of rating, which is why autonomy figures matter more than array size in winter. At 5,300 lb / 2,404 kg dry, the Beacon H6 Hybrid is a job for a three-quarter-ton or heavier pickup with trailer brakes set correctly.
Maintenance
Wipe panels during site visits, check that panel tilt and fasteners are tight after moves, and look for cracked glass. Check cable glands and connectors for chafe. The battery needs no watering, but its management system logs cell health; review it every few months. Keep the battery enclosure locked.
The mast is raised by hydraulic cylinders. Check fluid level and look for leaks on hoses and fittings at service, and use the remote lowering function ahead of forecast high winds.
The hitch is pintle or 2-5/16 in ball, tandem axle. Match the coupler to what your fleet tows with, and check ball size or lunette ring wear before every move.
Winter operation
Winter is the limiting season. Days are short, the sun is low and snow can cover the panels. Plan around the deep-winter autonomy figure, not the summer one, and see Solar harvest by season and latitude for how latitude changes harvest.
Specifications
| Lamps | 6 × 200 W LED, 5000 K |
|---|---|
| Light output | 120,000 lumens |
| Mast height | 30 ft / 9.1 m, hydraulic |
| Solar array | 1,600 W monocrystalline |
| Battery bank | 20.5 kWh LiFePO₄ |
| Generator | 8 kW diesel, auto start on low battery |
| Fuel tank | 40 gal / 150 L, about 30 days typical |
| Auxiliary outlets | 2 × 120 V, 1 × 240 V |
| Hitch | Pintle or 2-5/16 in ball, tandem axle |
| Dry weight | 5,300 lb / 2,404 kg |
| Power options | Solar, methanol fuel cell, 120 V shore power or diesel generator |
Specifications describe the standard diesel generator build. Mast, cameras, battery and uplink can be changed on a custom build.