
- Solar
- 7.2 kW
- Storage
- 60 kWh
- Output
- 20 kW
Solar wings, a 60 kWh battery and an integrated generator. Power for remote camps, pump stations and multi-unit security deployments.
How the diesel generator works on the Fieldgrid P20 Hybrid
An auto-start generator charges the battery only when its state of charge drops to a set point, then shuts down when the battery is full. Most of the time the unit runs silently from the battery, and on solar-equipped trailers the panels still do most of the work in good weather. The generator is insurance for long dark spells and heavy loads.
A generator turns a power trailer into a full hybrid station. The battery and solar handle light loads quietly, and the generator starts for heavy loads or low charge, which keeps run hours far below a genset running all day.
In its standard build, the Fieldgrid P20 Hybrid carries a 61 kWh LiFePO₄ battery bank and a 7.2 kW fold-out, 18 panels array. The standard build also has a 20 kW diesel, auto start generator.
When to choose this configuration
Choose a diesel generator for heavy loads, sites that run 24 hours a day, and long northern winters where solar harvest is small for months. It is the most robust choice when the unit must never go dark and fuel deliveries are already part of site life.
This is the standard configuration of the Fieldgrid P20 Hybrid, so the specification table on this page describes it directly.
Why people choose the Fieldgrid P20 Hybrid
The P20 Hybrid combines a 7.2 kW fold-out array, a 61 kWh battery, a 20 kW inverter in split-phase or three-phase and a 20 kW auto-start diesel generator. Cam-lock outputs feed site distribution. The catalogue quotes up to 85% fewer generator run hours, and it can power several camera and light towers.
- A remote camp, pump station or multi-unit deployment needs a power hub
- You need three-phase 120/208 V or cam-lock distribution
- Generator run hours and fuel cost need to come down
Refuelling
Refuel with winter-grade diesel in cold months to avoid waxing. The app reports fuel level and generator run time, so refuelling can be scheduled rather than reactive. Fill from approved containers or a fuel truck, use the spill-contained fuel bay and keep absorbent pads on hand. Never fill while the generator is running.
This configuration in numbers
The generator on the standard Fieldgrid P20 Hybrid is a 20 kW diesel, auto start unit. Its run time depends on the season and load; the runtime report in the app is the best guide to refuelling intervals, and the Generator fuel interval estimator turns it into a schedule. At 9,400 lb / 4,264 kg dry, the Fieldgrid P20 Hybrid is heavy-equipment towing that needs a heavy-duty truck and a rated pintle hook.
Maintenance
Service is based on run hours: oil and filter changes, air filter checks and fuel filter changes at the intervals in the generator manual. Check coolant, belts and the battery that starts the engine. Run the generator under load periodically if it has sat idle through a sunny spell, and drain water from the fuel filter.
The Fieldgrid P20 Hybrid uses a pintle hitch (pintle, tandem axle). Check the lunette ring for wear and close and pin the pintle latch before every move.
Winter operation
Use winter-blend fuel or an anti-gel additive, check block heater operation if fitted, and keep the exhaust and air intake clear of snow drifts. Auto-start makes diesel the most dependable option through December and January at high latitudes.
Specifications
| Solar array | 7.2 kW fold-out, 18 panels |
|---|---|
| Battery bank | 61 kWh LiFePO₄ |
| Inverter | 20 kW continuous, 120/240 V or 120/208 V 3-phase |
| Generator | 20 kW diesel, auto start |
| Outlets | Cam-lock panel plus receptacles |
| Monitoring | Cellular telemetry, app |
| Hitch | Pintle, tandem axle |
| Dry weight | 9,400 lb / 4,264 kg |
| Power options | Solar, methanol fuel cell, 120 V shore power or diesel generator |
Specifications describe the standard diesel generator build. Mast, cameras, battery and uplink can be changed on a custom build.